RAID & IOPS calculator
Calculate usable capacity, fault tolerance, IOPS, rebuild time and rebuild exposure window of a RAID array. Everything runs in your browser.
Results
- Usable capacity
- TB (vendor)
- TiB (what the OS shows)
- Efficiency
- Fault tolerance
- Functional IOPS
- IOPS
- read · write
- Write penalty
- Rebuild time
How it is calculated
Notation: N = total disks, H = hot spares, D = N − H (active disks), S = disk size in TB and G = number of groups in RAID 50/60. Figures are theoretical: use them for sizing, not as a performance guarantee.
Usable capacity by level
- RAID 0
- D × S
- RAID 1
- S (2-disk mirror)
- RAID 5
- (D − 1) × S
- RAID 6
- (D − 2) × S
- RAID 10
- (D ÷ 2) × S
- RAID 50
- (D − G) × S
- RAID 60
- (D − 2G) × S
Efficiency is usable capacity divided by total raw capacity (N × S, spares included).
RAID levels at a glance
| Level | Min. disks | Usable capacity | Tolerance | Write penalty | Typical use |
|---|---|---|---|---|---|
| RAID 0 | 1 (2 recommended) | D × S | 0 | 1 | Cache, disposable data |
| RAID 1 | 2 | S | 1 | 2 | OS or hypervisor boot |
| RAID 5 | 3 | (D − 1) × S | 1 | 4 | Read-heavy, small disks or SSD |
| RAID 6 | 4 | (D − 2) × S | 2 | 6 | Archive, backup, large-capacity HDD |
| RAID 10 | 4 (even) | (D ÷ 2) × S | 1 (up to D ÷ 2) | 2 | Databases, write-heavy VMs |
| RAID 50 | 6 | (D − G) × S | 1 per group (up to G) | 4 | Large arrays built from RAID 5 groups |
| RAID 60 | 8 | (D − 2G) × S | 2 per group (up to 2G) | 6 | Large double-parity HDD arrays |
Guaranteed tolerance is how many disks you can lose in any combination. For RAID 10, 50 and 60 the best case only holds if the failures land in different mirrors or groups.
Functional IOPS
Raw IOPS are D × IOPS per disk. Every logical write costs several physical operations (the write penalty), so functional IOPS depend on the read/write mix. With r = read percentage ÷ 100:
Functional IOPS = (D × IOPS per disk) ÷ (r + (1 − r) × write penalty)
Example: 6 × 15k disks at 180 IOPS in RAID 5 with 70% reads. Raw: 6 × 180 = 1,080. Functional: 1,080 ÷ (0.7 + 0.3 × 4) = 1,080 ÷ 1.9 ≈ 568 IOPS.
TB vs TiB
Vendors use decimal TB (10¹² bytes) while operating systems report binary TiB (2⁴⁰ bytes). The conversion is TiB = TB × 10¹² ÷ 2⁴⁰ ≈ TB × 0.9095. A 4 TB disk shows up as about 3.64 TiB, and 24 TB usable appears as about 21.83 TiB. Nothing is lost: it is only the unit.
Rebuild and the exposure window
Rebuild time is S ÷ reconstruction rate. It depends on disk size and on the rate the controller can sustain while it also serves production load.
While rebuilding, the array is degraded. RAID 5, each RAID 50 group, RAID 1 and the affected RAID 10 mirror pair have no redundancy left: another failure in that set loses data. RAID 6 and RAID 60 can still tolerate one more failure.
The real risk is that window: the longer it is, the likelier another disk fails. Disks from the same batch and of the same age share wear, and a rebuild puts them under sustained reads, so correlated failures do happen. A hot spare shortens the window because the rebuild starts without waiting for a person.
Secondarily, an unreadable sector (URE) during the rebuild can prevent reconstructing a block. Vendor URE specifications are worst-case ceilings, not measured rates, so this calculator does not turn them into a percentage.
With large disks, RAID 6 or RAID 10 plus a hot spare is the prudent choice: they either tolerate another failure or rebuild only the mirror partner.
Assumptions and limitations
- IOPS per disk are typical random 4K figures; real values depend on the model, queue depth and workload.
- Controller cache (write-back, BBU/flash) is not modelled; it greatly improves short random writes.
- On SSD and NVMe, write amplification, over-provisioning and wear affect sustained performance and endurance.
- Controllers and vendors implement RAID differently (stripe size, RAID 10 layouts, RAID 50/60 parity). Check your array documentation.
- Real rebuild time depends on production load, rebuild priority and disk size. Usable capacity excludes controller and file system metadata.
- ZFS (RAIDZ, mirrors, dRAID) and Ceph (replication, erasure coding) compute capacity and performance differently and are not covered here.
Coming soon: Ceph / ZFS calculator.
Frequently asked questions
How much usable space does RAID 6 give?
RAID 6 reserves the equivalent of two disks for parity, so usable capacity is (D − 2) × S. With 8 × 4 TB disks that is 24 TB usable (about 21.8 TiB in the operating system), 75% efficiency. It needs at least 4 disks and survives the failure of any two disks.
RAID 5 or RAID 6?
With large HDDs (2 TB or more) choose RAID 6: rebuilding a RAID 5 takes many hours or days and for that whole time the array cannot tolerate another failure. The longer the window, the likelier another disk (same batch and age) fails under rebuild load. RAID 5 is only reasonable with small disks or SSDs, a short rebuild and data you can restore from backup. RAID 6 costs one more disk of capacity and a higher write penalty (6 vs 4), but still tolerates a failure during the rebuild.
What is the write penalty?
It is the number of physical disk operations one logical write requires. RAID 0 has 1, RAID 1 and RAID 10 have 2 (written to both disks), RAID 5 has 4 (read data and parity, write both) and RAID 6 has 6 (because of the second parity). It divides the available write IOPS and, together with the read percentage, determines functional IOPS.
Why does the operating system show less space?
Because the vendor counts in decimal TB (10¹² bytes) while the operating system counts in binary TiB (2⁴⁰ bytes). A 4 TB disk is about 3.64 TiB. File system reserves and controller metadata come on top of that.
RAID 10 or RAID 6 for virtual machines?
For VMs with many random writes (databases, VDI, logs) RAID 10 is better: write penalty 2, fast rebuilds and no parity calculation, at the cost of 50% efficiency. RAID 6 yields more capacity per disk and suits cold data, backup repositories and read-heavy workloads, but with a write penalty of 6.
What is the exposure window during a rebuild?
It is the time the reconstruction takes after a disk failure. In RAID 5, RAID 50 (per group), RAID 1 and the RAID 10 mirror pair there is no redundancy left during that time, so another failure in that set loses data; RAID 6 and RAID 60 can still tolerate one more. The calculator shows the estimated rebuild time and whether the array tolerates another failure meanwhile. A hot spare and smaller disks shorten the window.